Gold Member Since 2015
Audited Supplier
Fujian Quanzhou Western Union Fire Fighting Tech Co., Ltd.

Cccf Irrigation Sprinkler, UL Listed Fire Sprinkler, Viking Fire Sprinkler manufacturer / supplier in China, offering CCCF UL FM irrigation sprinkler, Zsfm Deluge Valve, Ce Approval Fire Extinguisher Balls, Automatic Fire Extinguisher, Fire Ball and so on.

(/ )

Supplier Homepage Product Fire Sprinkler CCCF UL FM irrigation sprinkler

CCCF UL FM irrigation sprinkler

FOB Price: US $0.295-1 / Piece
Min. Order: 2,000 Pieces
Min. Order FOB Price
2,000 Pieces US $0.295-1/ Piece
Get Latest Price
Port: Xiamen, China
Production Capacity: 10000pieces/Week
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: ZSTZ&ZSTX&ZSTB&ZSTP
  • Sprinkler Head Type: Closed
  • Automatically Opened and Closed Repeatedly: Can′t Automatically Opened and Closed
  • Wet Alarm Valve Structure: Flange
  • Place of Origin: Fujian, China (Mainland)
  • Norminal Diameter ( mm): Dn15 or Dn20
  • Connecting Thread: 1/2"(15mm), 3/4"(20mm)
  • Glass Bulb Diameter: 5mm or 3mm
  • Glass Bulb Color: Orange,Red,Yellow,Green,Blue,Purple
  • Trademark: XL or customized
  • Specification: 37.5*20.5*29
  • HS Code: 8424899990
  • Sprinkler Installation: Pendent
  • Alarm Valve Type: Wet Alarm Valve
  • Open Fire Sprinkler System Type: Water Spray System
  • Nozzle Flow Coefficient: 80
  • Model Number: Zstz&Zstx&Zstb&Zstp
  • Material: Brass, Chrome Finished
  • Brand Name: OEM
  • Flux Coefficient: 80 or 115
  • Temprature Rate: 57,68,79,93,141,182degree
  • Transport Package: Carton Box
  • Origin: Fujian, China
Product Description
FOB Price:US $ 0 - 1 / Piece
Min.Order Quantity:2000 Pieces
Supply Ability:10000 Pieces/per Week
Port:xiamen
Payment Terms:L/C,D/P,T/T

 
Quick Details
Place of Origin: Fujian, China (Mainland)
Brand Name: OEM
Model Number: ZSTZ&ZSTX&ZSTB&ZSTP
Norminal diameter ( mm):DN15 or DN20
Material: brass, chrome finished
Connecting thread:1/2"(15mm), 3/4"(20mm)
Glass bulb diameter:5mm or 3mm

Packaging & Delivery

Packaging Details:
carton packing: 37.5cmx20.5cmx29cm 200 pieces in one carton packing. 10.6KG weight each one carton
Delivery Detail:10,000 pieces can be ready for delivery within one week

 
Declare:
Glass ball closed sprinkle nozzle is the most key components of automatic sprinkler system, used to detect the instrument of fire element,And to control fire and extinguish firethrough the automatic water spray device. Apply to work environment temperature less than 4 °C, and is not higher than 70 °C in light of the danger level buildings as wet system to fight fire water of the hotel, department stores, restaurants, entertainment, warehouse, hospitals, factories, the airport and the basement automatic sprinkler system such as the pipe network.
 
Principle of operation:
This series of ball sprinkler head working principle is filled with high thermal expansion coefficient of organic solution of the glass ball as a heat sensitive components. At normal temperature, and the glass ball shell we can withstand the support, ensure wards of the seal. When the fire breaks out temperature, glass ball inside the organic solution happen and generates a lot of thermal pressure inside, until the glass ball shell happen broken, and open water spray nozzle.
 
Structure characteristics:
This series of ball sprinkle nozzle is made of copper alloy frame, glass ball, seal, glass ball seat, tight set screws and splash water dish wait for assembly and into. Compact structure, shape exquisite and beautiful
3.1,Nozzle framework USES the high strength copper alloy precision forging, high strength,corrosion resistance.
3.2, Temperature temperature sensing elements (ball) with high quality products at home and abroad, glass ball high strength, reliable, and reaction speed.

 
technical characteristics and types and specifications:
4.1, nominal diameter: φ 15 mm, connected to thread: R1/2 ", the flow characteristic factor: K = 80 ± 4.
4.2, nominal diameter: φ 20 mm, connected to thread: R3/4 ", the flow characteristic factor: K = 115 ± 9.
4.3, rated pressure: 1.2 Mpa(12 Bars), The factory test pressure: 3.0 Mpa(30Bars).
4.4, glass ball diameter: φ 3 mm, φ 5 mm.
4.5

Technical parameters

Type

Nominal diameter(mm)

Connecting thread

Flow coefficient

T-ZSTP
Conventional sprinkler

DN15

R1/2

80±4

DN20

R3/4

115±6

T-ZSTX
Pendent sprinkler

DN15

R1/2

80±4

DN20

R3/4

115±6

T-ZSTZ
Upright sprinkler

DN15

R1/2

80±4

DN20

R3/4

115±6

T-ZSTBS
Sidewall sprinkler

DN15

R1/2

80±4

DN20

R3/4

115±6

ZSTDY
Concealed sprinkler

DN15

R1/2

80±4

DN20

R3/4

115±6
 

Technical parameters

Rated operating temperature

Max.ambient temperature

Glass bulb colour

57°C

27°C

Orange

68°C

38°C

Red

79°C

49°C

Yellow

93°C

63°C

Green

141°C

111°C

Blue

182°C

152°C

Purple
Send your message to this supplier
Avatar
Miss Eva
Sales Manager
*From:
To: Miss Eva
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now